Validation of the Smart Mask V1 System and Its Measurements of SpO2 and Pulse Rate

Status: Recruiting
Location: See location...
Intervention Type: Device
Study Type: Interventional
Study Phase: Not Applicable
SUMMARY

The goal of this clinical study is to investigate a new medical device, the Smart Mask V1 System (herein 'Smart Mask'), and particularly its measurements of blood oxygen levels (SpO2) and pulse rate (PR) in healthy adults aged 18 to 65. More specifically, the study is directed at answering the following questions: * Can the Smart Mask accurately measure SpO2 levels compared to established reference devices (reference oximeters, blood gas) throughout the range of SpO2 \ 70 - 100%? * Can the Smart Mask accurately measure PR during the same conditions? * Does skin pigmentation impact the accuracy of Smart Mask's measurements of SpO2 and PR. The following reference devices will be used in the study: * An FDA-cleared fingertip pulse oximeter (Nellcor Portable SpO2 Patient Monitoring System, PM10N) * A laboratory-grade CO-oximeter (Radiometer ABL90 FLEX) that analyzes oxygen saturation from blood samples. Study participants will: * Wear the Smart Mask on their face and a fingertip pulse oximeter while lying down * Breathe air with gradually reduced oxygen levels inside a specialized hypoxia room while being closely. * In a second phase of the study, have a catheter inserted into a wrist artery for blood sampling to directly measure oxygen levels with the CO-oximeter.

Eligibility
Participation Requirements
Sex: All
Minimum Age: 18
Maximum Age: 65
Healthy Volunteers: t
View:

• Healthy subjects with ASA health score of I or II

• Subjects aged between ≥ 18 and ≤ 65 years.

• Subjects who have provided informed consent and are willing to comply with the study procedures.

Locations
Other Locations
Belgium
Complementair Medisch Centrum (CMC) Europe
RECRUITING
Genk
Contact Information
Primary
Raf De Jongh, M.D.
raf.dejongh@skynet.be
+32 477 514 77
Time Frame
Start Date: 2025-09-01
Estimated Completion Date: 2025-12-31
Participants
Target number of participants: 36
Treatments
Experimental: Non-Invasive (NI)
The Non-Invasive (NI) study is designed to calibrate the Smart Mask's algorithms using data collected from healthy volunteers exposed to controlled, progressive hypoxia. During the study, participants lie in a supine position in a normobaric hypoxia room while breathing room air with gradually reduced oxygen levels, with the fraction of inspired oxygen (FiO2) decreasing from approximately 21% to as low as 9.5%. The Smart Mask derives SpO2 values from reflected light signals detected by its integrated sensors. Simultaneously, a benchmark pulse oximeter (Nellcor PM10N), worn on the finger, provides reference SpO2 and pulse rate (PR) values for algorithm calibration. Data from reference device are used to refine the conversion of raw photoplethysmography (PPG) signals into SpO2 and PR readings. This phase serves as a feasibility study and is a prerequisite for advancing to subsequent phase. 12 healthy subjects will be enrolled in this study.
Experimental: Invasive (IN)
If the Non-Invasive (NI) phase demonstrates feasibility, the Invasive (IN) study will follow to validate the Smart Mask's measurements against a gold-standard method. This phase involves arterial blood gas analysis to directly measure arterial oxygen saturation (SaO2) using CO-oximetry. Participants undergo the same progressive hypoxia protocol within a controlled hypoxia room. An indwelling radial artery catheter is inserted to allow periodic arterial blood sampling at five predefined oxygen plateaus. The SaO2 values obtained from the CO-oximeter reference device (ABL90 FLEX) are then compared to the SpO2 values calculated by the Smart Mask. 24 healthy volunteers will be enrolled in this phase.